hello, first of all u have to make u r iop 0 at least at sby level, as it is in sys level in u r ap records. So either u have make it at sby or else change u r ap data thr datpat.. provided u know the datpat cmds. CDOT Banglore persons can help u. And to make u r iop's in duplex, files is there in PRCDATAP call sync***** files, while ssynchronizing iop's compare those files. so u hav to save those file with any other name, and nullify the existing files. If i m not wrong this procedure will work for u.
--- On Tue, 8/9/09, subhash rohilla <happy_rohillasubhash@yahoo.co.in> wrote:
From: subhash rohilla <happy_rohillasubhash@yahoo.co.in> Subject: Re: [TTABSNL] GOT A PROBLEM IN CDOT NEED HELP To: TTABSNL@yahoogroups.com Date: Tuesday, 8 September, 2009, 3:37 PM
hello delete fgp, ioh files secondly look into iop data if any data or ncbr or traffic files present delete all files then try to sync subhash rohilla 09467070200
--- On Mon, 7/9/09, PK Nath <nath.indian@ yahoo.co. in> wrote:
From: PK Nath <nath.indian@ yahoo.co. in> Subject: Re: [TTABSNL] GOT A PROBLEM IN CDOT NEED HELP To: TTABSNL@yahoogroups .com Date: Monday, 7 September, 2009, 9:33 PM
Hi ! Please note down the file names while aborting out and see the file may be corrupted and mostly these r ncbr files. U have to erase them but should have a backup. ED & BD should be taken out for every action as u know. Try it'll be okay. Nath PK TTA, Mhow Indore
--- On Mon, 7/9/09, ramesh kannan <rameshkannan79@ yahoo.co. in> wrote:
From: ramesh kannan <rameshkannan79@ yahoo.co. in> Subject: [TTABSNL] GOT A PROBLEM IN CDOT NEED HELP To: TTABSNL@yahoogroups .com Date: Monday, 7 September, 2009, 8:31 PM
Hi friends I got a problem in CDOT.IOP-1 is active and not able to sync the iop-0. After booting with Unix,patch,Base and BMDC and with ED and BD taken from iop-1 as soon as the sync starts the counter starts running in step 0 and after that step around 23 mins later an error message replied as "SYNC ABORTED COULDNT ABLE TO SENT MESSAGE TO MATE IOP" Also tried to bring the stand by iop individually but The iop level command shows that communication with AP as No Communication with iop is not taking place when iop-0 indivually put into service Hope any one in CDOT can make some suggestion to rectify the above problem. ER J RAMESH TTA INSTALLATION NAGERCOIL SSA TAMILNADU CIRCLE 91 9443163585
|